Discover LG CANADA HVAC

Indoor Units - Non Ducted
Wall Mounted

Wall Mounted

Power Supply: 208-230V / 60Hz / 1ø

Model No.: ARNU073SEL2

Consult your Rep for pricing

PRODUCT SUPPORT

These low profile units are popular in many applications. These are a lower cost alternative to mirror units and contain a filter system.

 Operation

  • Auto changeover (Heat Recovery only)
  • Auto operation
  • Auto clean (coil dry)1
  • Child lock
  • Dual thermistor control
  • Forced operation
  • Group control
  • Hot start
  • Self diagnostics
  • Sleep mode
  • Timer (on/off)
  • Weekly schedule
  • Soft dry (dehumidification)

Airflow

  • Auto direction/swing (up/down)
  • Auto direction/swing (left/right)2
  • Manual direction (left/right)3
  • Fan speed control
  • Chaos swing (random louver swing)
  • Chaos wind (random fan speed)
  • Jet cool (fast cooling)

Filter

  • Washable pre-filter
  • Plasma
  • Carbon

Controllers

  • 7-day programmable controller
  • Simple controller with mode
  • Simple controller without mode
  • Wireless handheld controller

1: Requires wireless handheld controller

2: S5 models only

3: SE models only

Available models: ARNU073SEL2, ARNU093SEL2, ARNU123SEL2, ARNU153SEL2, ARNU183S5L2, ARNU243S5L2,

Model   ARNU073SEL2

Capacity

Cooling

Btu/h

7,500

Heating

Btu/h

8,500

Power Input

Cooling

Watts

40

Heating

Watts

40

Power Supply

V / Hz / ø

208-230 / 60 /  1

Dimensions(W×D×H)

Body

inch

35.2 x 6.5 x 11.1

Weight

lbs

20

Sound Pressure (H/M/L)4

dBA

37/33/23

Air Flow Rate (H/M/L)

cfm

198/177/163

Note :
1. Capacities are based on the following conditions
    Cooling-Indoor temp. 80°F DB / 67°F WB               Heating-Indoor temp. 70°F DB
    Outdoor temp. 95°F DB                                        Outdoor temp. 47°F DB / 43°F WB
    Interconnecting Piping Length 25ft (7.5m)  Interconnecting Piping Length 25ft (7.5m)
    Level Difference of 0ft (0m) Level Difference of 0ft (0m)
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. Sound pressure levels as tested in an anechoic chamber under Korea Standard KSA0701

Download Type Category Product Name Model No.
Download Submittals Indoor Units - Non Ducted Wall Mounted - GEN 2 ARNU073SEL2
Download Engineering Manuals Indoor Units All Products NA
Download Catalogs Indoor Units Multi V™ Indoor Units NA
Download Installation Manuals Indoor Units - Non Ducted Wall Mounted NA
Download Owners Manuals Indoor Units - Non Ducted Wall Mounted NA
Download BIM / REVIT Indoor Units NA
Download 2D CAD Models Indoor Units - Non Ducted NA
Download Product Warranty Warranty Card 2/7 Multi V™ IV, Water IV, Space II, Indoor Units, DOAS & ERV NA