Power Supply: 208-230V / 60Hz / 1ø

Model No.: ARNU153BGA2

Consult your Rep for pricing

PRODUCT SUPPORT

The slim high-static, low profile ducted indoor units, can in many instances be fitted in between joists to create higher ceiling for dramatic affect.

Operation

  • Auto changeover (Heat Recovery only)
  • Auto operation
  • Auto restart
  • Child lock
  • Dual thermistor control
  • Group control
  • E.S.P. control
  • Hot start
  • Self diagnostics
  • Sleep mode
  • Timer (on/off)
  • Weekly schedule
  • Soft dry (dehumidification)


Airflow

  • Fan speed control


Filter

  • Washable pre-filter


Controllers

  • 7-day programmable controller
  • Simple controller with mode
  • Simple controller without mode
  • Wireless handheld controller¹


Other

  • Condensate lift2
  • Ventilation (Outside Air)3


1: Requires 7-day programmable controller
2: 27 ½ inches from bottom of unit
3: Temperature, humidity, and volume limitations apply
See Engineering Manual for condition limits

Model ARNU153BGA2

Capacity

Cooling

Btu/h

15,400

Heating

Btu/h

17,100

Power Input

Cooling

Watts

450

Heating

Watts

450

Power Supply

V / Hz / ø

208-230 / 60 / 1

Dimensions(W×D×H)3

Body

inch

53.0 x 19.2 x 11.7

Weight

lbs

84

Sound Pressure (H/M/L)4

dBA

37/36/33

Air Flow Rate High Mode (H/M/L)5

CFM

487/417/293

External Static Pressure6

in wg

0.39

Air Flow Rate Standard Mode (H/M/L)5

CFM

477/427/318

External Static Pressure6

in wg

0.31

Note :
1. Capacities are based on the following conditions
    Cooling-Indoor temp. 80°F DB / 67°F WB      Heating-Indoor temp. 70°F DB
    Outdoor temp. 95°F DB                             Outdoor temp. 47°F DB / 43°F WB
    Interconnecting Piping Length 25ft (7.5m)  Interconnecting Piping Length 25ft (7.5m)
    Level Difference of 0ft (0m)                        Level Difference of 0ft (0m)
2. Capacities are net capacities.
3. Dimensions are for casing only and do not include hangers, control boxes, and pipes. See engineering manual for dimensions details.
4. Sound pressure levels as tested in an anechoic chamber under ISO Standard 1996.
5. Factory shipped with high mode setting. Fan speed can be adjusted to compensate for additional external static pressure losses. See Engineering Manual for details.
6. External Static Pressure, as shipped from the factory, does not include air filter or connected ductwork, but applies to any fan speed.
7. Due to our policy of innovation some specifications may be changed without notification.

Download Type Category Product Name Model No.
Download Submittals Indoor Units - Ducted Ceiling-concealed High Static ARNU153BGA2
Download Engineering Manuals Indoor Units All Products NA
Download Catalogs Indoor Units Multi V™ Indoor Units NA
Download Installation Manuals Indoor Units - Ducted Ducted (High, Low, Built-In) Indoor Units NA
Download Owners Manuals Indoor Units - Ducted Ceiling Concealed High Static NA
Download Service Manuals Indoor Units - Ducted Multi V Ceiling Concealed High Static Duct Units NA
Download BIM / REVIT Indoor Units NA
Download 2D CAD Models Indoor Units - Ducted NA
Download Product Warranty Warranty Card 2/7 Multi V™ IV, Water IV, Space II, Indoor Units, DOAS & ERV NA