Discover LG CANADA HVAC

Indoor Units - Ducted
Ceiling Concealed Built-In

Ceiling Concealed Built-In

Power Supply: 208-230V / 60Hz / 1ø

Model No.: ARNU073B3G2

Consult your Rep for pricing

PRODUCT SUPPORT

The slim low-static, low profile ducted indoor units, can in many instances be fitted in between joists to create higher ceiling for dramatic affect.

Operation

• Auto changeover (Heat Recovery only)

• Auto operation

• Auto restart

• Child lock

• Dual thermistor control

• Group control

• E.S.P. control

• Hot start

• Self diagnostics

• Sleep mode

• Timer (on/off)

• Weekly schedule

• Soft dry (dehumidification)

Airflow

• Fan speed control

Filter

• Washable pre-filter

Controllers

• 7-day programmable controller

• Simple controller with mode

• Simple controller without mode

• Wireless handheld controller¹

Other

• Condensate lift2

• Ventilation (outside air)3

• Suction grill4

• Suction canvas4

1: Requires 7-day programmable controller

2: 27 ½ inches from bottom of unit

3: Temperature, humidity, and volume limitations apply

See Engineering Manual for condition limits

4: Suction grill and suction canvas are optional (See page 90)

 

Available models: ARNU073B3G2, ARNU093B3G2, ARNU123B3G2, ARNU153B3G2, ARNU183B4G2, ARNU243B4G2,

Model   ARNU073B3G2

 

 

 

Capacity

Cooling

Btu/h

7,500

   

kW

2.2

 

Heating

Btu/h

8,500

 

 

kW

2.5

Power Input

Cooling

kW

0.03

 

Heating

kW

0.03

Power Supply

 

V / Hz / ø

208-230 / 60 / 1

Dimensions(W×D×H)

Body

inch

32.3 x 22.6 x 7.5

 

 

mm

820 x 575 x 190

Weight

 

lbs(kg)

46.3(21)

Sound Pressure (H/M/L)4

 

dBA

37/34/33

Air Flow Rate (H/M/L)

(High Mode-factory set)

cfm

282/229/194

External Static Pressure4

(High Mode-factory set)

in wg

0.08

Air Flow Rate (H/M/L)

(Standard Mode)

cfm

282/229/194

External Static Pressure4

(Standard Mode)

in wg

0

       

Note :       
1. Capacities are based on the following conditions       
    Cooling-Indoor temp. 80°F DB / 67°F WB          Heating-Indoor temp. 70°F DB       
    Outdoor temp. 95°F DB                                 Outdoor temp. 47°F DB / 43°F WB      
    Interconnecting Piping Length 25ft (7.5m)    Interconnecting Piping Length 25ft (7.5m)       
    Level Difference of 0ft (0m) Level Difference of 0ft (0m)      
2. Capacities are net capacities       
3. Due to our policy of innovation some specifications may be changed without notification       
4. External Static Pressure, as shipped from the factory, does not include air filter or connected ductwork, but applies to any fan speed       

 

Download Type Category Product Name Model No.
Download Submittals Indoor Units - Ducted Ceiling-concealed Low Static Built-in ARNU073B3G2
Download Engineering Manuals Indoor Units All Products NA
Download Catalogs Indoor Units Multi V™ Indoor Units NA
Download Installation Manuals Indoor Units - Ducted Ducted (High, Low, Built-In) Indoor Units NA
Download Owners Manuals Indoor Units - Ducted Ceiling Concealed Low Static Built-in NA
Download BIM / REVIT Indoor Units NA
Download 2D CAD Models Indoor Units - Ducted NA
Download Product Warranty Warranty Card 2/7 Multi V™ IV, Water IV, Space II, Indoor Units, DOAS & ERV NA