Discover LG CANADA HVAC

Indoor Units - Non Ducted
2 Way Cassette

2 Way Cassette

Power Supply: 208-230V / 60Hz / 1ø

Model No.: ARNU183TLC2

Consult your Rep for pricing

PRODUCT SUPPORT

The two way cassette discharges in two directions. The two way is ceiling mounted and includes it's own filter system.

 Operation

  • Auto changeover (Heat Recovery only)
  • Auto operation
  • Auto restart
  • Child lock 
  • Dual thermistor control 
  • Group control
  • Forced operation
  • High ceiling
  • Hot start
  • Self diagnostics 
  • Sleep mode 
  • Timer (on/off)
  • Weekly schedule 
  • Soft dry (dehumidification) 

Airflow

  • Auto direction/swing (up/down) 
  • Fan speed control
  • Chaos wind (random fan speed)
  • Jet cool (fast cooling) 

Filter

  • Washable pre-filter
  • Plasma 

Controllers

  • 7-day programmable controller 
  • Simple controller with mode
  • Simple controller without mode
  • Wireless handheld controller

Other

  • Condensate lift1
  • Standard grill2

1: 27 ½ inches from bottom of unit

2: Standard grill is a required option (PT-HLC)

Available models: ARNU183TLC2, ARNU243TLC2

Model   ARNU183TLC2

Capacity

Cooling

Btu/h

19,100

Heating

Btu/h

21,500

Power Input

Cooling

Watts

70

Heating

Watts

70

Power Supply

V / Hz / ø

208-230 / 60 /  1

Dimensions(W×D×H)

Body

inch

32.6 x 21.6 x 8.9

Front Panel

inch

41.3 x 25.2 x 1.1

Weight

Body

lbs

49

Front panel

lbs

10

Sound Pressure (H/M/L)4

dBA

40/36/32

Air Flow Rate (H/M/L)

cfm

459/424/353

Note :
1. Capacities are based on the following conditions
    Cooling-Indoor temp. 80°F DB / 67°F WB               Heating-Indoor temp. 70°F DB
    Outdoor temp. 95°F DB                                        Outdoor temp. 47°F DB / 43°F WB
    Interconnecting Piping Length 25ft (7.5m)  Interconnecting Piping Length 25ft (7.5m)
    Level Difference of 0ft (0m) Level Difference of 0ft (0m)
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. Sound pressure levels as tested in an anechoic chamber under Korea Standard KSA0701

Download Type Category Product Name Model No.
Download Submittals Indoor Units - Non Ducted 2 Way Cassette - GEN 2 ARNU183TLC2
Download Engineering Manuals Indoor Units All Products NA
Download Catalogs Indoor Units Multi V™ Indoor Units NA
Download Owners Manuals Indoor Units - Non Ducted 2 Way Cassette NA
Download BIM / REVIT Indoor Units NA
Download Product Warranty Warranty Card 2/7 Multi V™ IV, Water IV, Space II, Indoor Units, DOAS & ERV NA